Value of the mean of the maximum grip force acquired by the rodents (recorded in newtons) across multiple trials (usually 3 or more), as part of Grip Strength test.
Registration Status:
Qualified
Permissible Values:
Data Type:
Number
Unit of Measure:
N
Ids:
Value
Code Name
Code
Code System
Code Description
Designations:
Designation:
Grip Strength test - mean maximum force value
Tags:
Designation:
Mean maximum force measured across trials
Tags:
Preferred Question Text
Designations:
Definition:
Value of the mean of the maximum grip force acquired by the rodents (recorded in newtons) across multiple trials (usually 3 or more), as part of Grip Strength test.
Tags:
Short Description,Definition
Reference Documents:
ID:
Title:
URI:
Provider Org:
Language Code:
en-us
Document:
PMCID: PMC3907016
Properties:
Key:
Keywords
Value:
Grip_Strength;Preclinical
Key:
Guidelines/Instructions
Value:
Record in newtons. Use in combination with ContextType UDEs to specify if the force was measured before or after injury. Use along with LimbTyp to specify which limb was measured. For rodents only.
Key:
Notes
Value:
Grip Test (for assessment of sensory/motor function after TBI in rodents)